| Infrared Thermometers | The professional's diagnostic tool.
With a broader temperature range and improved optics for measuring temperatures from a greater distance or measuring smaller objects from the same distance, the Fluke 63, 66 and 68 offer a combination of accuracy and value for professionals. Standard features also include a rugged rubber overmolding and a durable plastic storage case. Special models include: Fluke 574-NI NONINCENTIVE FM rated thermometer and the all new Fluke Model 576 Photo thermometer with built-in digital camera. |
| SPECIFICATIONS |  |  |  |  |  |  |  | Item No. | 7803-1201 | 7803-1202 | 7803-1203 | 7803-1210 | 7803-1211 | 7803-1212 | 7803-1213 | Model | Fluke 63 | Fluke 66 | Fluke 68 | Fluke 572 | Fluke 574 | Fluke 574-NI | Fluke 576 Photo | PRICE (USD) | $215.00 | $405.00 | $519.00 | $753.00 | $1,161.00 | $2,327.00 | $1,797.00 | Temperature range | -32 to 535 ºC | -32 to 600 ºC | -32 to 760 ºC | -30 to 900 ºC | -30 to 900 ºC | -30 to 900 ºC | -30 to 900 ºC | (25 to 999 ºF) | (25 to 1100 ºF) | (20 to 1400 ºF) | (-25 to 1600 °F) | (-25 to 1600 °F) | (-25 to 1600 °F) | (-25 to 1600 °F) | D:S (Distance to spot size) at 90% energy | 12:1 | 30:1 | 50:1 | 60:1 (50:1 with close focus option) | 60:1 (50:1 with close focus option) | 60:1 (no close focus option). | 60:1 (50:1 with close focus option) | Laser sighting | Single point, offset | extra bright 3-dot, coaxial | Emissivity | Preset 0.95 | Adjustable | Adjustable | Adjustable | Adjustable | Adjustable | Accuracy (Assumes ambient operating temperature of 23 ºC [73 ºF]) | ± 1 % of reading or ± 1 ºC (± 2 ºF), (whichever is greater over the balance of the range) | ± 0.75 % of reading or ± 0.75 ºC (± 1.5 ºF) (whichever is greater over the balance of the range) | Response time | 500 mSec | 250 mSec | 250 mSec | 250 mSec | 250 mSec | Display Hold | N/A | 7 sec | 7 sec | 7 sec | 7 sec | MAX, MIN, DIF and AVG | MAX only | All | Min. and Max only | Yes | Yes | Yes | Recall last reading | N/A | Yes | N/A | 100-point data logging | HI/LO alarm | N/A | Yes | Yes | HI=Yes LO=No | Yes | Yes | Yes | Bar graph display | N/A | N/A | N/A | Yes | Yes | Yes | Yes | Max Photos 640 x 480 pixels VGA | N/A | N/A | N/A | N/A | N/A | N/A | 26 jpeg files | Max Photos 320 x 240 pixels VGA | N/A | N/A | N/A | N/A | N/A | N/A | 100 jpeg files | Weight and dimensions (H x W x L) | 320 g (11 oz) and 200 x 160 x 55 mm (8 x 6 x 2 in) | 472 g (1 lb 1 oz.) and 16.7 x 5 x 19.8 cm (6.58 x 1.97 x 7.8 in) | 480 g (1 lb 1 oz) and 16.7 x 5 x 19.8 cm (6.58 x 1.97 x 7.8 in) | 580 g (1 lb 4 oz) and 23.8 x 5 x 16.7cm (9.57 x 1.97 x 6.58 in) | Power | 9 V alkaline | 2 AA Batteries | 2 AA Batteries/AC adapter | 2 AA Batteries/USB | Display hold | 7 seconds | 7 seconds | 7 seconds | 7 seconds | 7 seconds | LCD backlit | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Warranty | 2 years, conditional | 2 years, conditional | Software | N/A | N/A | Data graphing software (Windows XP, NT, 2000 compatible, RS232 port required) | Data graphing and image viewing software (Windows XP, NT, 2000 compatible, USB port required) | Kit Contents | Thermometer, 9V alkaline battery, operators guide, CD-ROM with user manual and a Latching Hard Case. | Thermometer, (2) AA batteries, user manual and latching hard case. | Thermometer, (2) AA batteries, AC power supply, thermocouple K, RS-232 cable, Windows compatible software, user manual and latching hard case. | Thermometer, (2) AA batteries, thermocouple K, USB cable, Windows compatible software, user manual and hard case. |
| APPLICATIONS | | Fluke Infrared Thermometers: Indispensable Tools in Facility Maintenance |  | The Fluke handheld noncontact thermometers easily determine whether motors, boilers, bearings, electrical systems, and all types of operating equipment are functioning properly, and detects signs of developing problems. Fluke thermometers quickly and conveniently measure surface temperatures from a safe distance to keep your plant operating efficiently and preventing costly shutdowns.
How do I measure temperature with an IR thermometer? There are three Fluke noncontact thermometer measurement techniques: Spot: determine the absolute surface temperature of an object. Temperature differential: compare two spot measurements against each other. Scanning: detect changes along a wide or continuous region target.
What are the benefits of using IR thermometers? Effectively find your problems quickly and safely, saving time and cost IR thermometers are accurate, usually within one degree IR thermometers safely read hard-to-reach or inaccessible objects | What are the main areas I can use my IR thermometer? Electrical Maintenance. Check for heat created by loose connectors or buildup. Instantly troubleshoot problems in battery banks and power panel terminations, ballasts, switch gears, and fuse connections, and identify hot spots in the output filters on DC battery connections. |  | Equipment Maintenance. Check moving parts in motors and gear work for hot spots. Temperature change can indicate developing problems in many types of equipment, from ovens and boilers to freezers. Routine temperature audits of generators and their bearings can prevent expensive repairs.
Building Controls. Monitor HVAC/R components for quick energy audits and room balancing in a short time. |  | Troubleshoot engine problems. Temperature is a vital indicator of how well cooling systems are performing, or whether friction, vibration and other conditions are creating wear in braking systems and bearings.
Process/Product. Monitor process line equipment. Check the temperature of different products on production lines from rubber tires to plastic and cellophane wrapping to chocolate bars. |
 | The Fluke 576 IR Thermometer The maintenance professionals precision diagnostic toolThe Fluke 576 non-contact thermometer is the ideal professional diagnostic tool for maintenance professionals requiring the most accurate temperature readings at all distances. The Fluke 576 unit measures surface temperatures, helping to quickly locate potential blockages or malfunctioning systems reducing work time and improving performance. From close-up electrical connections, to far-distance room balancing checks, the Fluke 576 can take IR temperature measurements with ease. · Backlit display for poorly lit areas · Holds last ten temperature readings and displays on bar graph for easy reference · Enhanced optics (distance to spot ratio up to 60:1) allows measurements of smaller objects from farther away · Coaxial three-dot laser sighting system highlights the true diameter of measurement spots at all distances · Adjustable emissivity for more accurate measurements · Close-focus option available for specialized applications · Durable plastic storage case Temperature Measurement Techniques · Spot measure: Determine the absolute surface temperature of an object · Temperature differential: Compare two spot measurements against each other · Scanning: Detect changes along a wide or continuous region target |  | |
to top |
| Infrared Noncontact Thermometers Are Effective Equipment Performance Monitoring & Diagnostic Tools |  Noncontact thermometers give you instant, accurate temperature readings of most key HVAC components. Diagnose duct leakage, supply and return air temperatures, plumbing lies, and other heat-related problems with Raytek infrared thermometers.
Technicians quickly and efficiently gather temperature data from these applications: Room Balancing: scan walls for unbalanced temperatures Duct Work: scan the surface of ductwork to reveal temperature spikes and poor insulation Steam Distribution Systems: diagnose blown or plugged steam traps from a safe distance Furnace Performance: test furnace performance by checking the flue temperature Supply/Return Registers: evaluate temperature differential between supply/return registers | Other Applications: | Check for coil sweating of condensate lines Check emergency relief value temperature Scan wet wallboard for water leaks Measure existing air from a coil and at a supply air grill |
to top |
| HAZARDOUS APPLICATIONS (Fluke 574-NI ONLY) |  With a broader temperature range and improved optics from measuring temperatures from a greater distance, the STPro Plus series offers a combination of accuracy and value. In addition, 574-NI model has Intrinsically Safe rating from Factory Mutual allowing noncontact temperature measurements in hazardous areas. This model also features optics (Distance to Spot 50:1) that allows the user to measure smaller objects from farther away, a rugged rubber overmolding, and a durable plastic storage case.

Hazardous Applications - Petrochemical - Hazardous Locations - Pumping Stations - Gas Storage - Tank Farms - Refineries |
| to topORDERING INFORMATION |  |  |  |  |  |  |  | Item No. | 7803-1201 | 7803-1202 | 7803-1203 | 7803-1210 | 7803-1211 | 7803-1212 | 7803-1213 |
Model |
Fluke 63 |
Fluke 66 |
Fluke 68 |
Fluke 572 |
Fluke 574 |
Fluke 574-NI |
Fluke 576 Photo | PRICE (USD) | $215.00 | $405.00 | $519.00 | $753.00 | $1,161.00 | $2,327.00 | $1,797.00 | | | 
|  |  |  |  |  |  |
|
|